Release note for Star Cool controller software 0356 rev 03


The key changes that have been implemented in software version Star Cool 0356 rev 03 are listed below: 

New functions and changes to existing functions:

1.  Alarm strategy changes.

Check of contactors improved to be able to detect for non-running evaporator fan motors in heating mode.
a)       Alarms added:     
Alarm 663 Mevap Hi contactor
Alarm 664 Mevap contactor – both Low and Hi malfunctioning 
Alarm 665 Hevap contactor


2.  Data logging.


In some occasions, data logging more than once at the same timestamp was observed, giving problems in ACT reporting, this has now been corrected.

3.  Battery mode.

Wrong/missing information shown in display when running in battery mode:
a)       PTI icon not displayed.
b)       Measured Tsuc, Tamb, and Tevap values shown as 0°C reading, this has now been updated to show the current value.

4.  StarConomy.

Container prefixes get configured default StarConomy value set to on/off according to the specification after software update.

5.  Display text.

Limiter text on the main display and the information given in menu line I40 is now synchronized.