The
key changes that have been implemented in software version Star Cool 0356 rev 03 are listed
below:
New functions and changes to existing functions:
New functions and changes to existing functions:
1.
Alarm strategy changes.
Check of
contactors improved to be able to detect for non-running evaporator fan motors
in heating mode.
a)
Alarms added:
Alarm 663
Mevap Hi contactor
Alarm 664 Mevap contactor – both Low and Hi malfunctioning
Alarm 665
Hevap contactor
2.
Data logging.
In some
occasions, data logging more than once at the same timestamp was observed,
giving problems in ACT reporting, this has now been corrected.
3. Battery mode.
Wrong/missing
information shown in display when running in battery mode:
a) PTI icon not displayed.
b)
Measured Tsuc, Tamb, and Tevap values shown as 0°C
reading, this has now been updated to show the current value.
4. StarConomy.
Container
prefixes get configured default StarConomy value set to on/off according to the
specification after software update.
5. Display text.
Limiter text on
the main display and the information given in menu line I40 is now
synchronized.
If you have any questions, please contact your Star Cool Service
Manager or send an email to: service@starcool.com